来源:未知 日期:2016/12/19 浏览量:次
General specifications | ||
---|---|---|
Detection type | photoelectric sampling | |
Pulse count | 1024 | |
Functional safety related parameters | ||
MTTFd | 140 a | |
Mission Time (TM) | 20 a | |
L10h | 2 E+9 | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 60 mA | |
Output | ||
Output type | push-pull, incremental | |
Voltage drop | < 4.4 V | |
Load current | max. per channel 40 mA , short-circuit prtected (not with Ub), reverse polarity protected | |
Output frequency | max. 200 kHz | |
Rise time | 400 ns | |
Connection | ||
Cable | ∅7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65, IP66, IP68 | |
Climatic testing | ||
Static climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
Cyclic climatic testing | DIN EN 60068-2-30 55 °C, 6 cycles | |
Salt spray test | DIN EN 60068-2-52 , 672 h | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Approvals and certificates | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
Ambient conditions | ||
Operating temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Material | ||
Housing | aluminum, coated, salt water resistant | |
Flange | aluminum, coated, salt water resistant | |
Shaft | stainless steel 1.4404 / AISI 316L | |
Mass | approx. 280 g | |
Rotational speed | max. 100 min -1 | |
Moment of inertia | ≤ 35 gcm2 | |
Starting torque | ≤ 4.5 Ncm | |
Shaft load | ||
Angle offset | 1 ° | |
Axial offset | max. 1 mm |