来源:未知 日期:2016/12/19 浏览量:次
General specifications | ||
---|---|---|
Pulse count | 1024 | |
Functional safety related parameters | ||
MTTFd | 140 a | |
Mission Time (TM) | 20 a | |
L10h | 50 E+9 at 1750 rpm | |
Diagnostic Coverage (DC) | 0 % | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
No-load supply current | max. 70 mA | |
Output | ||
Output type | HTL, incremental | |
Voltage drop | < 2.5 V | |
Load current | max. per channel 20 mA , short-circuit protected, reverse polarity protected | |
Output frequency | max. 120 kHz | |
Rise time | 980 ns | |
De-energized delay | 980 ns | |
Connection | ||
Connector | type 9416 (M23), 12-pin | |
Standard conformity | ||
Degree of protection | DIN EN 60529, IP65 | |
Climatic testing | ||
Static climatic testing | DIN EN 60068-2-3 40 °C, 93 % rel. humidity, no condensation | |
Cyclic climatic testing | DIN EN 60068-2-30 55 °C, 6 cycles | |
Salt spray test | DIN EN 60068-2-52 , 672 h | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
Oscillation with broad band noise | DIN EN 60068-2-64 5 ... 500 Hz, 1.9 gRMS | |
Free fall testing | DIN EN 60068-2-32 unpacked: 1 m, packed: 1.5 m | |
Ambient conditions | ||
Operating temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Isolation bushing | 16 mm , plastic | |
Material | ||
Housing | aluminium, salt water resitant | |
Flange | aluminium, salt water resitant | |
Shaft | High grade stainless steel | |
Mass | approx. 600 g | |
Rotational speed | max. 3000 min -1 | |
Starting torque | ≤ 6 Ncm | |
Shaft load | ||
Radial offset | max. 0.04 mm |