联系方式
联系人:王经理
 
电 话:021-39520660
 
手  机:15821591180
 
传 真:021-69001586
 
Q    Q:1257746205
 
Email:debon_gk@163.com
 

计数器 KC-LCDL-48-2R-24VDC

来源:未知    日期:2017/02/09    浏览量:


● Counter/Timer/Tachometer
● Adding/subtracting via 2 separate inputs
● Batch controller with 2 pre-selections
● Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs
● Display range and preselection range from -999999 up to 999999
● Overflow will be evaluated correctly up to 1 decade
● PNP and NPN sensors can be connected
● Degree of protection IP65 (front only)


产品阐述:
LCD batch controller with 2 relay outputs and 24 VDC supply voltage
General specifications:
Pre-selection 2-fold
Data storage > 10 years, EEPROM
Programming keypad-driven menu
Functional safety related parameters:
MTTFd 410 a
Mission Time (TM) 10 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means:
Type 2-line, 2 x 6-digit LC display with leading sign
backlighted
Display value digit height 9 mm
Pre-selection digit height 7 mm
Key interlock via "high" potential at "LOCK" input
Decimal point 0 to max 5 fractional digits
Scale factor 0.0001 ... 99.9999
Reset manually or external
Electrical specifications:
Fusing 10 … 30 V DC: T 0.2 A
Operating voltage 10 ... 30 V DC
Power consumption max. 1.5 W
Input:
Connection Counter inputs: A and B
Control/reset inputs: LOCK, RESET, GATE, MPI
Signal voltage  
  High 0.6 x Ue ... 30 V DC
  Low 0 ... 0.2 x Ue
Counting frequency 30 Hz / 55 kHz
Minimum pulse duration Control/reset inputs: 10 ms / 1 ms
Impedance 5 kOhm
Count modes  
  Pulse counter Counting with counting direction (cnt.dir),
difference counting (up.dn),
up/down counting (quad),
Cumulative counting (up.up),
up/down counting x 2 (quad 2),
up/down counting x 4 (quad 4),
additional functions for counter input A and counter input B:
A/B, (A-B)/A x 100% 
  Frequency counter functions for input A and input B:
A, A-B, A+B quad, A/B, (A-B)/A x 100 %
  Timer Time measurement via GATE input (FrErun),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.),
time measuring via RESET input (auto)
Output:
Relay changeover contact , Make contact
  Switching voltage max. 250 V AC / 110 V DC
  Switching current max. 3 A AC/DC, min. 30 mA DC,
  Switching power max. 750 VA / 90 W
Sensor supply connected power supply is looped through,
max. 80 mA
Output I Relay with make contact, NC or NO progr.
  Mechanical life 2 x 107 switching cycles
  Electrical life 1 x 105 switching cycles at 3 A
Output II Relay with changeover contact
  Mechanical life 2 x 107 switching cycles
  Electrical life 5 x 104 cycles at 3 A
Response time Relay: approx. 7 ms
Frequency counter: 100/600 ms
Compliance with standards and directives:
Directive conformity  
  EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999
Standard conformity  
  Emitted interference DIN EN 55011:2009, Class B
  Mech. capacity EN 60068-2-6:2008
10 … 55 Hz / 1 mm / XYZ
30 min in each direction
  Shock and impact resistance EN 60068-2-27:1995
100 G / 2 ms / XYZ
3 times in each direction
Ambient conditions:
Ambient temperature -20 ... 65 °C (-4 ... 149 °F)
Storage temperature -25 ... 75 °C (-13 ... 167 °F)
Relative humidity ≤ 93 % at 40 °C (noncondensing)
Altitude 0 ... 2000 m
Mechanical specifications:
Degree of protection IP65 (front)
Mass approx. 138 g
Dimensions 48 mm x 48 mm x 109.8 mm