来源:未知 日期:2017/02/09 浏览量:次
产品阐述: | ||
---|---|---|
LCD batch controller with 1 relay output and 24 VDC supply voltage |
General specifications: | ||
---|---|---|
Pre-selection | single | |
Data storage | > 10 years, EEPROM | |
Programming | keypad-driven menu | |
Indicators/operating means: | ||
Type | 2-line, 2 x 6-digit LC display with leading sign | |
Display value | digit height 9 mm | |
Pre-selection | digit height 7 mm | |
Key interlock | via "high" potential at "LOCK" input | |
Decimal point | 0 to max 5 fractional digits | |
Scale factor | 0.0001 ... 99.9999 | |
Reset | manually or external | |
Electrical specifications: | ||
Fusing | 11 … 30 V DC: T 0.2 A | |
Operating voltage | 11 ... 30 V DC | |
Power consumption | max. 4 W | |
Input: | ||
Connection |
Counter inputs: A and B Control/reset inputs: LOCK, RESET |
|
Signal voltage | ||
High | 3.5 ... 30 V DC | |
Low | 0 ... 2 V DC | |
Counting frequency | 30 Hz / 5 kHz | |
Minimum pulse duration | Control/reset inputs: static / 1 ms | |
Impedance | 10 kOhm | |
Count modes | ||
Pulse counter |
Counting with counting direction (cnt.dir), difference counting (up.dn), up/down counting (quad), |
|
Timer |
Time measurement via GATE input (FrErun), counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.), |
|
Output: | ||
Relay | changeover contact | |
Switching voltage | max. 250 V AC / 110 V DC | |
Switching current | max. 3 A AC/DC, min. 30 mA DC, | |
Switching power | max. 750 VA / 90 W | |
Mechanical life | 2 x 107 switching cycles | |
Electrical life | 5 x 104 cycles at 3 A | |
Response time |
< 15 ms pulse counter < 10 ms time counter |
|
Sensor supply |
connected power supply is looped through, max. 50 mA |
|
Compliance with standards and directives: | ||
Directive conformity | ||
EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 50295:1999 | |
Standard conformity | ||
Emitted interference | DIN EN 55011:2009, Class B | |
Mech. capacity |
EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction |
|
Shock and impact resistance |
EN 60068-2-27:1995 100 G / 2 ms / XYZ 3 times in each direction |
|
Ambient conditions: | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Storage temperature | -25 ... 75 °C (-13 ... 167 °F) | |
Relative humidity |
≤ 93 % at 40 °C (noncondensing) |
|
Altitude | 0 ... 2000 m | |
Mechanical specifications: | ||
Degree of protection | IP65 (front) | |
Mass | approx. 117 g | |
Dimensions | 48 mm x 48 mm x 109.8 mm |