来源:未知 日期:2017/02/20 浏览量:次
General specifications: | ||
---|---|---|
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-G6*-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
Versions |
LMC10P6-G6P-O4 LMC10D5-G6D-O4 |
|
Output: | ||
Connection | 3-wire, potentiometer connection approx. 40 kΩ | |
Directive conformity: | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity: | ||
Degree of protection | IEC 60529:2000 | |
Measurement accuracy: | ||
Accuracy | resolution: 10 mm | |
Operating conditions: | ||
Process conditions | ||
Process temperature |
version PP: -10 ... 80 °C (14 ... 176 °F) version PVDF: -10 ... 100 °C (14 ... 212 °F) |
|
Process pressure (static pressure) | ≤ 3 bar (43.5 psi) | |
Density | ≥ 0.8 g/cm3 | |
Ambient conditions: | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications: | ||
Degree of protection | IP65 | |
Connection | 3 terminals, max. 2.5 mm2 | |
Material |
float, guide tube, process connection: - version PP: PP (Polypropylene) - version PVDF: PVDF (Polyvinylidenfluoride) terminal box: Polyester |
|
Dimensions |
float: - version PP: cylinder ∅55 mm x 54 mm - version PVDF: cylinder ∅55 mm x 70 mm guide tube: ∅14 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm |
|
Process connection | thread G2A to DIN/ISO 228/1 | |
Accessories: | ||
Optional accessories |
LML-FD5 float, cylinder, Ø55 mm x 70 mm, PVDF LML-FP6 float, cylinder, Ø55 mm x 54 mm, PP |
上一篇:磁性液位测量仪 LMC-Ex