来源:未知 日期:2017/02/20 浏览量:次
General specifications: | ||
---|---|---|
Equipment architecture | A measuring system consists of a magnet-operated immersion probe LMC****-***-I with built-in converter and a transmitter power supply KFD2-STC4-1 or of a magnet-operated immersion probe LMC****-***-O4 and a potentiometer converter KFD2-PT2-Ex1. | |
Output: | ||
Connection |
version I: 2-wire, 4 ... 20 mA version O4: 3-wire, potentiometer connection approx. 40 kΩ |
|
Directive conformity: | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 , EN 61326-2-3:2013 | |
Conformity: | ||
Degree of protection | IEC 60529:2000 | |
Measurement accuracy: | ||
Accuracy |
resolution: - version LMC5: 5 mm - version LMC15: 15 mm |
|
Operating conditions: | ||
Process conditions | ||
Process temperature | -20 ... 120 °C (-4 ... 248 °F) | |
Process pressure (static pressure) | ≤ 16 bar (232.1 psi) | |
Density |
version S1: ≥ 0.6 g/cm3 version S2: ≥ 0.8 g/cm3 version S3: ≥ 0.7 g/cm3 |
|
Ambient conditions: | ||
Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
Mechanical specifications: | ||
Degree of protection | IP65 | |
Connection |
Version I: 2 terminals, max. 2.5 mm2 Version O4: 3 terminals, max. 2.5 mm2 |
|
Material |
float, guide tube, process connection: stainless steel 1.4571/316Ti terminal box: aluminum die-casting |
|
Dimensions |
float: - version S1: ball ∅80 mm - version S2: cylinder ∅44 mm x 52 mm - version S3: ball ∅52 mm guide tube: - version LMC5: ∅14 mm, max. length 3000 mm - version LMC15: ∅12 mm, max. length 3000 mm terminal box: 80 x 75 x 55 mm |
|
Process connection | thread G1/2A, G1-1/2A to DIN/ISO 228/1 | |
Accessories: | ||
Optional accessories |
LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti LML-FS5 float, ball, Ø52 mm, Titanium LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti |
上一篇:磁性液位测量仪 LMC-P
下一篇:压力变送器 LHC-M51