联系方式
联系人:王经理
 
电 话:021-39520660
 
手  机:15821591180
 
传 真:021-69001586
 
Q    Q:1257746205
 
Email:debon_gk@163.com
 

磁性液位测量仪 LMC-Ex

来源:未知    日期:2017/02/20    浏览量:


● Sensor for continuous level measurement in liquids
● Resolution 5 mm or 15 mm
● Media contacting parts of stainless steel
● Mounting without removing the float
● Approved for zone 0


General specifications:
Equipment architecture A measuring system consists of a magnet-operated immersion probe LMC****-***-I-Ex with built-in converter and a transmitter power supply KFD2-STC4-Ex1 or of a magnet-operated immersion probe LMC****-***-O4-Ex and a potentiometer converter KFD2-PT2-Ex1.
Output:
Connection version I: 2-wire, 4 ... 20 mA
version O4: 3-wire, potentiometer connection approx. 40 kΩ
Directive conformity:
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61000-6-2:2006 , EN 61000-6-4:2011
Conformity:
Degree of protection IEC 60529:2000
Measurement accuracy:
Accuracy resolution:
- version LMC5: 5 mm
- version LMC15: 15 mm
Operating conditions:
Process conditions  
  Process temperature -20 ... 100 °C (-4 ... 212 °F)
  Process pressure (static pressure) ≤ 16 bar (232.1 psi)
  Density version S1: ≥ 0.6 g/cm3
version S2: ≥ 0.8 g/cm3
version S3: ≥ 0.7 g/cm3
Ambient conditions:
Ambient temperature terminal box: -50 ... 60 °C (-58 ... 140 °F)
Mechanical specifications:
Degree of protection IP65
Connection Version I: 2 terminals, max. 2.5 mm2
Version O4: 3 terminals, max. 2.5 mm2
Material float, guide tube, process connection: stainless steel 1.4571/316Ti
terminal box: aluminum die-casting
Dimensions float:
- version S1: ball ∅80 mm
- version S2: cylinder ∅44 mm x 52 mm
- version S3: ball ∅52 mm
guide tube:
- version LMC5: ∅14 mm, max. length 3000 mm
- version LMC15: ∅12 mm, max. length 3000 mm
terminal box: 80 x 75 x 57 mm
Process connection thread G1-1/2A, G2A to DIN/ISO 228/1
Data for application in connection with hazardous areas:
EC-Type Examination Certificate KEMA 03 ATEX 1497 X
  Group, category, type of protection, temperature class Ex-Hexagon II 1/2G EEx ia IIC T4...T6
  Voltage 28 V
  Current 120 mA
  Internal capacitance 0 nF
  Internal inductance 0 µH
Directive conformity  
  Directive 2014/34/EU EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
Accessories:
Optional accessories LML-FS1 float, ball, Ø80 mm, 1.4571/316Ti
LML-FS4 float, ball, Ø44 mm, 1.4571/316Ti
LML-FS5 float, ball, Ø52 mm, Titanium
LML-FS6 float, cylinder, Ø44 mm x 52 mm, 1.4571/316Ti

上一篇:没有了