General specifications: | ||
---|---|---|
Design / Mounting | Motherboard based | |
Supply: | ||
Rated voltage | 19.2 ... 35 V DC SELV/PELV | |
Rated current | 210 ... 120 mA | |
Power dissipation | max. 4.2 W | |
Fieldbus interface: | ||
Fieldbus type | FOUNDATION Fieldbus | |
Physical layer profile | profile type 114 | |
ITK version | 6 | |
Implementation |
resource block1x RS function block4x MDI, 1x MDO, 1x MAI, 1x DI transducer block16x ADM TB, 1x IO TB |
|
Firmware update | Ethernet | |
Polarity | polarity-sensitive | |
Rated voltage | 9 ... 35 V SELV/PELV | |
Rated current | 0 mA | |
Connection to power link | ||
Connection | ||
Ethernet Interface: | ||
Rated voltage | max. 35 V SELV/PELV | |
Port | 100 BASE-TX | |
Protocol | TCP/IP and UDP/IP | |
Services | ICMP , DHCP , AutoIP , HTTP | |
Connection type | RJ-45 socket, 8-pin | |
Transfer rate | 100 MBit/s | |
Diagnostic Bus: | ||
Connection | only for the connection to protected circuits | |
Rated voltage | max. 35 V | |
Number of Diagnostic Bus Channels | 2 | |
Number of Diagnostic Modules/Channel | 31 Using Ethernet Interface , 8 Using Fieldbus Interface | |
Termination | integrated | |
Cable length/Channel | 30 m | |
Indicators/operating means: | ||
LED ERR | red: Hardware fault | |
LED PWR | green: Power on | |
Fault signal | buzzer on | |
LINK/ACT | yellow | |
CH1, CH2 | yellow: diagnostic bus activity | |
Inputs: | ||
Input I, II | ||
Input type | selectable: Frequency input , NAMUR/mechanical contact | |
Frequency | ||
Connection | only passive load | |
Rated voltage | max. 35 V | |
Input frequency | 0.3 Hz to 1 kHz | |
Pulse duration | min. 50 µs | |
Accuracy | ± 1 % | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short-circuit | |
NAMUR | ||
Sensor type | NAMUR sensor according to DIN EN 60947-6 | |
Connection | only passive load | |
Rated voltage | max. 35 V | |
Switching frequency | 10 Hz | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
Input III, IV | ||
Input type | NAMUR/mechanical contact | |
NAMUR | ||
Sensor type | NAMUR sensor according to DIN EN 60947-6 | |
Connection | only passive load | |
Rated voltage | max. 35 V | |
Switching frequency | 10 Hz | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
Input V | ||
Input type | selectable: diagnostic bus CH 1 alarm input , NAMUR/mechanical contact | |
Alarm Input | ||
Connection | only passive load | |
Rated voltage | max. 35 V | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
NAMUR | ||
Sensor type | NAMUR sensor according to DIN EN 60947-6 | |
Connection | only passive load | |
Rated voltage | max. 35 V | |
Switching frequency | 10 Hz | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
Input VI | ||
Input type | selectable: diagnostic bus CH 2 alarm input , NAMUR/mechanical contact | |
Alarm Input | ||
Connection | only passive load | |
Rated voltage | max. 35 V | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short-circuit | |
NAMUR | ||
Sensor type | NAMUR sensor according to DIN EN 60947-6 | |
Connection | only passive load | |
Rated voltage | max. 35 V | |
Switching frequency | 10 Hz | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
Input VII, VIII | ||
Input type | selectable: Pt100 4-wire temperature input , NAMUR/mechanical contact | |
Temperature | ||
Connection | only passive load | |
Rated voltage | max. 35 V | |
Measurement range | -50 ... 90 °C (-58 ... 194 °F) | |
Accuracy | 1 K | |
Measuring current | 1 mA | |
Lead resistance | 4.2 Ω per line | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short-circuit | |
NAMUR | ||
Sensor type | NAMUR sensor according to DIN EN 60947-6 | |
Connection | only passive load | |
Rated voltage | max. 35 V | |
Switching frequency | 10 Hz | |
Cable length | max. 30 m | |
Line fault detection | lead breakage , short circuit | |
Humidity | ||
Measurement range | 0 ... 95 % RH | |
Accuracy | 2 % RH | |
Resolution | 0.04 % | |
Outputs: | ||
Output I | ||
Output type | selectable: diagnostic bus CH 1 , relay , NO contact | |
Contact loading | 250 V AC/ 6 A resistive load | |
Mechanical life | 1 x 105 switching cycles | |
Response time | turn-on time 7 ms , turn-off time 3 ms | |
Switching frequency | 6 min-1 full load, 1200 min-1 without load | |
Output II | ||
Output type | selectable: diagnostic bus CH 2 , relay , NO contact | |
Contact loading | 250 V AC/ 6 A resistive load | |
Mechanical life | 1 x 105 switching cycles | |
Response time | turn-on time 7 ms , turn-off time 3 ms | |
Switching frequency | 6 min-1 full load, 1200 min-1 without load | |
Output III | ||
Output type | selectable: common alarm , volt-free contact , NC contact | |
Connection | only for the connection to protected circuits | |
Voltage | 50 V DC | |
Current | max. 1 A | |
Output IV | ||
Output type | common alarm , buzzer | |
Galvanic isolation: | ||
All circuits/FE | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Output I, II/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff | |
Ethernet/Supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Ethernet/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Fieldbus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Diagnostic Bus/other circuits | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff | |
Directive conformity: | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 | |
Low voltage | ||
Directive 73/23/EEC | EN 61010 | |
Standard conformity: | ||
Galvanic isolation | IEC 62103 | |
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529 | |
Fieldbus standard | IEC 61158-2 | |
Climatic conditions | DIN IEC 721 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 | |
Ethernet | IEEE 802.3 | |
Ambient conditions: | ||
Ambient temperature |
-40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting |
|
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | < 95 % non-condensing | |
Shock resistance | 5 g 11 ms | |
Vibration resistance | 1 g , 10 ... 150 Hz | |
Pollution degree | max. 2, according to IEC 60664 | |
Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
Mechanical specifications: | ||
Housing material | Polycarbonate | |
Housing width | see dimensions | |
Housing height | see dimensions | |
Housing depth | see dimensions | |
Degree of protection | IP20 | |
Mass | 500 g | |
Mounting | DIN rail mounting | |
Data for application in connection with hazardous areas: | ||
FOUNDATION Fieldbus | ||
Connection | For connection to circuits with safe limited voltage according to IEC 60079-11:2011, type of protection "ic" | |
Voltage Ui | max. 35 V | |
Certificate | TÜV 14 ATEX 115980 X | |
Marking | Motherboard MB-FB-GT.AD.FF.IO II 3 G Ex nA nC IIC T4 Gc , Gateway II 3 G Ex nA IIC T4 Gc | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals: | ||
IECEx approval | IECEx TUN 14.0003X | |
Approved for | Motherboard Ex nA nC IIC T4 Gc , Gateway Ex nA IIC T4 Gc |