来源:未知 日期:2018/07/11 浏览量:次
一般特性: | ||
---|---|---|
Switching element function |
Analog current or voltage output, programmable 2 switch outputs, programmable |
|
Object distance | 0.5 ... 3 mm , recommended: 1.5 mm | |
Measurement range | 0 ... 40 mm | |
Linearity range | 1 ... 39 mm | |
额定值: | ||
Operating voltage |
12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) |
|
Reverse polarity protection | reverse polarity protected | |
Linearity error |
within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
|
Repeat accuracy | ± 0.1 mm | |
Resolution | 50 µm | |
Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) | |
No-load supply current | ≤ 40 mA | |
Operating voltage indicator | LED green | |
功能安全性参数: | ||
MTTFd | 382 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
指示灯/操作键: | ||
LED S1 | switching state Switching output 1 | |
LED S2 | switching state Switching output 2 | |
LED S3 | Damping element in the configured analog measuring range | |
LED STATUS | Status display LED, green/red (Power on, communication/error, missing damping element) | |
接口: | ||
Interface type | IO-Link (via C/Q = Pin 4) | |
Device profile | Smart Sensor | |
Transfer rate | COM 2 (38.4 kBaud) | |
Value range | 0000h ... 3200h | |
IO-Link Revision | 1.1 | |
Min. cycle time | 2.3 ms | |
Process data witdh |
Process data input: 16 Bit Process data output: none |
|
SIO mode support | yes | |
Device ID | 0x200204 (2097668) | |
Compatible master port type | A | |
开关输出: | ||
Output type | 2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof | |
Operating current | ≤ 100 mA / output | |
Switching window | ± 1 mm | |
Switching hysteresis | 0.2 mm | |
Voltage drop | ≤ 3 V | |
Short-circuit protection | pulsing | |
模拟输出: | ||
Output type | 1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable | |
Load resistor |
current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
|
Short-circuit protection | voltage output: current limit | |
与标准和规范体系的一致性: | ||
Standard conformity | ||
Standards |
EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 |
|
许可和认证: | ||
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
周围环境: | ||
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) | |
机械特性: | ||
Connection type | 5-pin, M12 x 1 connector | |
Degree of protection | IP67 / IP69K | |
Material | ||
Housing | PBT, stainless steel 1.4571 , brass, nickel-plated | |
Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) | |
Mass | 56 g | |
与危险区域有关的应用数据: | ||
Equipment protection level | Gc (nA) , Dc | |
设备保护水平GC(NA): | ||
Type of protection | "n" | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF 15 CERT 3754 X | |
ATEX marking | II 3G Ex nA IIC T6 Gc | |
Standards | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature |
Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 30 °C (86 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F) |
|
设备保护水平Dc: | ||
Type of protection | Protection by enclosure "tc" | |
CE marking | [*PD-Z02586A*] | |
Certificates | ||
ATEX certificate | PF 15 CERT 3774 X | |
ATEX marking | II 3D Ex tc IIIC T80°C Dc | |
Standards | EN 60079-0:2012/A11+2013 , EN 60079-31:2014 | |
Possible characteristics | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax | |
Maximum permissible ambient temperature |
Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 30 °C (86 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F) |
|
一般信息: | ||
Use in the hazardous area | see instruction manuals |