General specifications |
|
AS-Interface specification |
V3.0 |
|
Earth fault detection |
integrated |
|
EMC monitoring |
integrated |
|
Diagnostics function |
integrated |
|
UL File Number |
E223772 |
|
Functional safety related parameters |
|
MTTFd |
105 a at 30 °C |
|
Indicators/operating means |
|
Display |
address display, error message LED display, 3 digits, for addressing and error messages |
|
LED PROFIBUS |
PROFIBUS master detected; LED green |
|
LED AS-i ACTIVE |
AS-Interface operation normal; LED green |
|
LED CONFIG ERR |
configuration error; LED red |
|
LED PRG ENABLE |
autom. programming; LED green |
|
LED POWER |
voltage ON; LED green |
|
LED PRJ MODE |
projecting mode active; LED yellow |
|
LED U AS-i |
AS-Interface voltage; LED green |
|
Switch SET |
Selection and setting of a slave address |
|
Button MODE |
Mode selection PRJ-operation/save configuration/cursor |
|
Electrical specifications |
|
Insulation voltage |
≥ 500 V |
|
Rated operating voltage |
from AS-Interface |
|
Rated operating current |
≤ 200 mA from AS-Interface |
|
Interface |
|
Interface type |
RS-485 |
|
Protocol |
PROFIBUS DP V0 and V1 |
|
Transfer rate |
9.6 kBit/s ... 12 MBit/s , Automatic baud rate detection |
|
Connection |
|
PROFIBUS |
Sub-D interface |
|
AS-Interface |
spring terminals, removable |
|
Compliance with standards and directives |
|
Standard conformity |
|
|
|
Electromagnetic compatibility |
EN 61000-6-2, EN 61000-6-4 |
|
|
Degree of protection |
EN 60529 |
|
|
Shock and impact resistance |
EN 61131-2 |
|
Ambient conditions |
|
Ambient temperature |
0 ... 55 °C (32 ... 131 °F) |
|
Storage temperature |
-25 ... 85 °C (-13 ... 185 °F) |
|
Mechanical specifications |
|
Degree of protection |
IP20 |
|
Mass |
approx. 460 g |
|
Construction type |