模拟量输入安全栅 KFD2-HLC-Ex1.D

来源:未知    日期:2018/05/29    浏览量:


倍加福隔离式安全栅不但有限能的功能,还有隔离功能,它主要由回路限能单元,信号和电源隔离单元、信号处理单元组成。隔离式安全栅采用了将输入、输出以及电源三方之间相互电气隔离的电路结构,同时符合本安型限制能量的要求。

K系列隔离式安全栅能够为用户提供全方位的解决方案,K系列安全栅保证现场设备和控制室之间可靠&经济的信号传送。无论用户单一的选择信号隔离模块或者进行大规模的系统集成,K系列产品都能提供面向应用的解决方案。

变送器供电模块接收普通或者智能变送器的4…20 mA信号的同时,为该变送器供电。该模块将危险区的测量值(例如温度、压力、流量等)成比例的变送成电流信号送往安全区。

二线制变送器的供电和信号从同一对导线上传输。智能型变送器不仅供电和传输普通的4…20mA信号,同时还将数字信号叠加在模拟信号上。

产品特点:● 1-channel isolated barrier
                 ● 24 V DC supply (Power Rail)
                 ● HART field device input with transmitter power supply
                 ● Usable as signal splitter (1 input and several outputs)
                 ● 3 analog outputs 4 mA ... 20 mA
                 ● Sink and source mode output
                 ● Configurable by keypad


一般特性:
Signal type Analog input
Supply:
Connection Power Rail or terminals 23+, 24-
Rated voltage 19 ... 30 V DC
Rated current approx. 120 mA at 24 V DC
Power dissipation 2.3 W
Power consumption 2.9 W
HART信号通道(本质安全):
Conformity HART field device input (revision 5 to 7)
接口:
Programming interface programming socket
输入:
Connection side field side
Connection terminals 1, 2, 3, 4, 5, 6
Open circuit voltage/short-circuit current typ. 24 V / 28 mA
Input resistance 250 Ω , 5 % (terminals 2, 3 and with jumper on 5, 6)
Available voltage ≥ 15.5 V at 20 mA, short-circuit protected
输出:
Connection side control side
Connection output I: terminals 7, 8, 9 , output II: terminals 13, 14, 15 , output III: terminals 19, 20, 21
Output signal analog
Current range 4 ... 20 mA , (source or sink mode)
Load max. 650 Ω , source mode
Voltage range 5 ... 30 V , sink mode from external supply
Fault signal downscale I ≤ 2 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43) or hold measurement value
Other outputs HART communicator on terminals 22, 24
Collective error message Power Rail and LED red
传递特性:
Output I, II, III  
  Resolution max. 2 µA
  Accuracy < 20 µA, 10 µA typ.
  Influence of ambient temperature < ± 2 µA/K
  Duration of measurement/Response delay HART message acquisition time plus 100 ms
电流隔离:
Output I/II/III/power supply functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
指示灯/设置:
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
via PACTware
Labeling space for labeling at the front
指令符合:
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage  
  Directive 2014/35/EU EN 61010-1:2010
符合:
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Protection against electrical shock IEC 60664-1
周围环境:
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
机械特性:
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
与危险区域性应用参数:
EU-Type Examination Certificate BASEEFA 07 ATEX 0174
  Marking Ex-Hexagon II (1)GD [Ex ia] IIC, [Ex iaD]
  Input Ex ia, Ex iaD
Supply  
  Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
Equipment terminals 1, 4/3 (with link between terminals 4 and 5)
  Voltage Uo 25.2 V
  Current Io 104.9 mA
  Power Po 0.661 W
Equipment terminals 2, 5/3
  Voltage Ui < 28 V
  Power Pi < 1.33 W
  Voltage Uo 1.1 V
  Current Io 11.9 mA
  Power Po 4 mW
Output I, II, III terminals 7, 8, 9; 13, 14, 15; 19, 20, 21 non-intrinsically safe
  Maximum safe voltage 253 V (Attention! Um is no rated voltage.)
Certificate PF 07 CERT 1142 X
  Marking Ex-Hexagon II 3G Ex nA II T4 X
Galvanic isolation  
  Input/Other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity  
  Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
国际认证:
FM approval  
  Control drawing 116-0129
IECEx approval  
  IECEx certificate IECEx BAS 07.0047
  IECEx marking [Ex ia] IIC , [Ex iaD]
一般信息:
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

 电气接线图
模拟量输入安全栅 KFD2-HLC-Ex1.D


隔离式安全栅在安装中时的注意事项:
1.隔离式安全栅应安装在安全场所,并环境条件能满足本手册《通用技术指标》中的“使用条件”的要求。
2.隔离式安全栅本安端(蓝色标记)和非本安端电路的接线导线在汇线槽中应分开铺设,各自采用独立的保护套管。本安侧的配线套管内不允许有其它电源线,包括其本安电路使用的电源线。
3.通往危险场所的导线应选用有蓝色标记的本安导线,导线线的软铜面积必须大于0.5mm2,绝缘强度应大于500V。
4.在对隔离式安全栅进行通电调试前,必须注意隔离式安全栅的型号、接线方法、线路极性等,是否符合设计及产品要求中的规定,否则可能对人身及设备造成伤害。
5.严禁用兆欧表测试隔离安全栅端子之间的绝缘强度。如要检查系统的绝缘强度,应先断开全部的接线,否则可能引起安全栅内部快速熔断器熔断。
6.在现场对安全栅进行编程前,必须先将所有接线断开再接入编程器,然后通电编程,否则可能引起不良后果。
7.与隔离式安全栅相连的现场仪表,均应通过经国家认定的防爆检验部门的防爆试验、并取得防爆合格证的仪表。
8.在设计、安装、使用、维护隔离式安全栅时,应同时遵守本产品手册中的说明及《GB3836.15-2000爆炸性气体环境用电气设备 第十五部分:危险场所电气安装(煤矿除外)》、《GB50058-1992 爆炸和火灾危险环境电力设置设计规范》。


      如果您对以上产品有兴趣或有疑问,请联系我们的在线客服或拨打021-39520660,上海锝秉工控专业的采购顾问将为您提供最优的采购咨询服务。