来源:未知 日期:2017/08/17 浏览量:次
一般特性: | ||
---|---|---|
Detection type | photoelectric sampling | |
Pulse count | max. 5000 | |
功能安全性参数: | ||
MTTFd | 140 a | |
Mission Time (TM) | 20 a | |
L10h | 70 E+9 at 6000 rpm | |
Diagnostic Coverage (DC) | 0 % | |
电气特性: | ||
Operating voltage | 5 V DC ± 5 % | |
No-load supply current | max. 70 mA | |
输出: | ||
Output type | RS 422, incremental | |
Load current | max. per channel 20 mA , conditionally short-circuit proof (not with Ub) | |
Output frequency | max. 200 kHz | |
Rise time | 100 ns | |
连接: | ||
Cable | ∅7.8 mm, 6 x 2 x 0.14 mm2, 1 m | |
符合标准: | ||
Degree of protection | DIN EN 60529, IP54 | |
Climatic testing | DIN EN 60068-2-78 , no moisture condensation | |
Emitted interference | EN 61000-6-4:2007/A1:2011 | |
Noise immunity | EN 61000-6-2:2005 | |
Shock resistance | DIN EN 60068-2-27, 100 g, 3 ms | |
Vibration resistance | DIN EN 60068-2-6, 10 g, 10 ... 2000 Hz | |
许可和认证: | ||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | |
周围环境: | ||
Operating temperature | ||
Glass disk |
-5 ... 80 °C (23 ... 176 °F) , movable cable -20 ... 80 °C (-4 ... 176 °F), fixed cable |
|
Plastic disk |
-5 ... 60 °C (23 ... 140 °F) , movable cable -20 ... 60 °C (-4 ... 140 °F), fixed cable |
|
Storage temperature | ||
Glass disk | -40 ... 85 °C (-40 ... 185 °F) | |
Plastic disk | -40 ... 70 °C (-40 ... 158 °F) | |
机械特性: | ||
Material | ||
Housing | powder coated aluminum | |
Flange | 3.1645 aluminum | |
Shaft | Stainless steel 1.4305 / AISI 303 | |
Mass | approx. 290 g | |
Rotational speed | max. 6000 min -1 | |
Moment of inertia | ≤ 40 gcm2 | |
Starting torque | ≤ 1.5 Ncm | |
Shaft load | ||
Angle offset | 1 ° | |
Axial offset | max. 1 mm |