来源:未知 日期:2016/12/19 浏览量:次
| General specifications | ||
|---|---|---|
| Type | Inclination sensor, 2-axis | |
| Measurement range | 0 ... 360 ° | |
| Absolute accuracy | ≤ ± 0.5 ° | |
| Response delay | ≤ 25 ms | |
| Resolution | ≤ 0.1 ° | |
| Repeat accuracy | ≤ ± 0.1 ° | |
| Temperature influence | ≤ 0.027 °/K | |
| Functional safety related parameters | ||
| MTTFd | 300 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Indicators/operating means | ||
| Operation indicator | LED, green | |
| Teach-In indicator | 2 LEDs yellow (switching status), flashing | |
| Button | 2 push-buttons ( Switch points programming , Evaluation range programming ) | |
| Switching state | 2 yellow LEDs: Switching status (each output) | |
| Electrical specifications | ||
| Operating voltage | 10 ... 30 V DC | |
| No-load supply current | ≤ 25 mA | |
| Time delay before availability | ≤ 200 ms | |
| Switching output | ||
| Output type | 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected | |
| Operating current | ≤ 100 mA | |
| Voltage drop | ≤ 3 V | |
| Analog output | ||
| Output type |
2 current outputs 4 ... 20 mA (one output for each axis) |
|
| Load resistor |
0 ... 200 Ω at UB = 10 ... 18 V 0 ... 500 Ω at UB = 18 ... 30 V |
|
| Compliance with standards and directives | ||
| Standard conformity | ||
| Shock and impact resistance | 100 g according to DIN EN 60068-2-27 | |
| Standards |
EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
| Approvals and certificates | ||
| UL approval | cULus Listed, Class 2 Power Source | |
| CSA approval | cCSAus Listed, General Purpose, Class 2 Power Source | |
| E1 Type approval | 10R-04 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Mechanical specifications | ||
| Connection type | 8-pin, M12 x 1 connector | |
| Housing material | PA | |
| Degree of protection | IP68 / IP69K | |
| Mass | 240 g | |