联系方式
联系人:王经理
 
电 话:021-39520660
 
手  机:15821591180
 
传 真:021-69001586
 
Q    Q:1257746205
 
Email:debon_gk@163.com
 

Timer, Counter KC-LCD-48-1R-230VAC

来源:未知    日期:2016/12/09    浏览量:


参数表节选:的技术参数 KC-LCD-48-1R-230VAC

产品阐述
LCD batch controller with 1 relay output and 230 VAC supply voltage
General specifications
Pre-selection single
Data storage > 10 years, EEPROM
Programming keypad-driven menu
Indicators/operating means
Type 2-line, 2 x 6-digit LC display with leading sign
Display value digit height 9 mm
Pre-selection digit height 7 mm
Key interlock via "high" potential at "LOCK" input
Decimal point 0 to max 5 fractional digits
Scale factor 0.0001 ... 99.9999
Reset manually or external
Electrical specifications
Fusing T 0.1 A
Operating voltage 230 V AC
Power consumption max. 6.5 VA
Input
Connection Counter inputs: A and B
Control/reset inputs: LOCK, RESET
Signal voltage  
  High 3.5 ... 30 V DC
  Low 0 ... 2 V DC
Counting frequency 30 Hz / 5 kHz
Minimum pulse duration Control/reset inputs: static / 1 ms
Impedance 10 kOhm
Count modes  
  Pulse counter Counting with counting direction (cnt.dir),
difference counting (up.dn),
up/down counting (quad),
  Timer Time measurement via GATE input (FrErun),
counter input A: Start, counter input B: Stop (InpA.InpB.),
counter input B: Start/Stop (InpB.InpB.),
Output
Relay changeover contact
  Switching voltage max. 250 V AC / 110 V DC
  Switching current max. 3 A AC/DC, min. 30 mA DC,
  Switching power max. 750 VA / 90 W
  Mechanical life 2 x 107 switching cycles
  Electrical life 5 x 104 cycles at 3 A
  Response time < 15 ms pulse counter
< 10 ms time counter
Sensor supply 14.4 ... 27.6 V DC
max. 50 mA at 230 VAC
Compliance with standards and directives
Directive conformity  
  Low Voltage Directive 2006/95/EC EN 61010-1:2001; protection class: 2
  EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999
Standard conformity  
  Emitted interference DIN EN 55011:2009, Class B
  Mech. capacity EN 60068-2-6:2008
10 … 55 Hz / 1 mm / XYZ
30 min in each direction
  Shock and impact resistance EN 60068-2-27:1995
100 G / 2 ms / XYZ
3 times in each direction
Ambient conditions
Ambient temperature -10 ... 50 °C (14 ... 122 °F)
Storage temperature -25 ... 75 °C (-13 ... 167 °F)
Relative humidity ≤ 93 % at 40 °C
(noncondensing)
Altitude 0 ... 2000 m
Pollution degree 2
Mechanical specifications
Degree of protection IP65 (front)
Mass approx. 230 g
Dimensions 48 mm x 48 mm x 109.8 mm

上一篇:没有了
下一篇:Timer, Counter, Tachometer KC-LCDC-48-2R-230VAC