来源:未知 日期:2016/12/15 浏览量:次
产品阐述 | ||
---|---|---|
Measuring automation light grid with a beam gap of 25 mm, IO-Link interface, push-pull output, fixed cable with M12 plug |
General specifications | ||
---|---|---|
Effective detection range | Standard : 0.3 ... 6 m | |
Threshold detection range | 7.5 m | |
Light source | IRED | |
Light type | modulated infrared light , 850 nm | |
Field height | see Table 1, max. 3200 mm | |
Beam spacing | 25 mm | |
Number of beams | see Table 1, max. 129 | |
Angle of divergence | 10 ° | |
Functional safety related parameters | ||
MTTFd | 34 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 60 % | |
Indicators/operating means | ||
Control elements | Receiver: 2 touch buttons for programming | |
Electrical specifications | ||
Operating voltage | 18 ... 30 V DC | |
Interface | ||
Interface type | IO-Link ( pin 4 ) | |
IO-Link Revision | 1.0 | |
COM-Mode | COM 2 (38.4 kBaud) | |
Min. cycle time | 2.3 ms | |
Process data witdh | 16 bit | |
Output | ||
Switching type | Factory setting: dark on , Switchable to light-on mode | |
Signal output |
Command interface: Pin 4 IO-Link interface C or used as switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) Switch output: Pin 5 switching output Q; 1 short-circuit proof reverse polarity protected push-pull output (receiver) synchronized with pin 4 |
|
Compliance with standards and directives | ||
Directive conformity | ||
EMC Directive 2004/108/EC | EN 60947-5-2:2007 | |
Standard conformity | ||
Product standard |
EN 60947-5-2:2007 IEC 60947-5-2:2007 |
|
Mechanical specifications | ||
Degree of protection | IP67 | |
Connection |
Emitter: 200 mm connecting cable with 4-pin, M12x1 connector Receiver: 200 mm connecting cable with 8-pin, M12 x 1 connector Cable cross section min. 0.25 mm2 Max. cable length 30 m |
|
Material | ||
Housing | extruded aluminum section , Silver anodized | |
Optical face | Plastic pane , Polycarbonate |