来源:未知 日期:2017/06/28 浏览量:次
产品阐述: | ||
---|---|---|
Safety Monitor, 8 decentralized output circuits |
一般特性: | ||
---|---|---|
AS-Interface specification | V3.0 | |
UL File Number | E223772 | |
功能安全性参数: | ||
Safety Integrity Level (SIL) | SIL 3 | |
Performance level (PL) | PL e | |
Mission Time (TM) | 20 a | |
PFHd | 5.08 E-9 | |
指示灯/操作键: | ||
LED SM |
Status of safety monitor, multicolored LED green: Safety monitor OK |
|
LED S1 ... S8 |
Status of inputs S1 ... S8, yellow LED yellow: Contact open |
|
LED O1, O2 |
Status of outlputs, multicolored LED yellow: Output on |
|
电气特性: | ||
Auxiliary voltage (input) | 20 ... 30 VDC PELV | |
Insulation voltage | 500 V AS-Interface/UAUX: | |
Rated operating voltage | 18,0 ... 31.6 V from AS-Interface | |
Rated operating current |
≤ 200 mA from AS-Interface; ≤ 4 A from AUX |
|
接口 1: | ||
Interface type | Chip card slot | |
接口 2: | ||
Interface type | Micro USB | |
输入: | ||
Number/Type |
8 / 4 safe inputs cat. 4 or 8 standard inputs |
|
Supply | 24 V UAUX | |
Current loading capacity |
10 mA per signal output 1.4 A OSSD supply output |
|
Input current | Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs) | |
输出: | ||
Number/Type |
Output circuits 1 and 2 max. contact rating: 700 m ADC-13 at 24 V |
|
Supply | 24 V UAUX | |
与标准和规范体系的一致性: | ||
Directive conformity | ||
Machinery Directive 2006/42/EC |
EN 13849-1:2008/AC:2009 EN 62061:2005 |
|
EMC Directive 2004/108/EC |
EN 50295:1999 EN 61000-6-2:2005/AC:2005 EN 61000-6-4:2007/A1:2011 |
|
Standard conformity | ||
Electromagnetic compatibility |
EN 50295:1999 EN 61000-6-2:2005/AC:2005 EN 61000-6-4:2007/A1:2011 |
|
AS-Interface | EN 50295:1999 | |
Degree of protection | EN 60529:2000 | |
Electrical safety |
IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849-1:2008/AC:2009 EN 61326-3-1:2008 |
|
编程指令: | ||
Profile | S-0.B.E | |
IO code | 0 | |
ID code | B | |
ID1 code | F | |
周围环境: | ||
Ambient temperature | 0 ... 55 °C (32 ... 131 °F) | |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
机械特性: | ||
Degree of protection | IP20 | |
Connection |
removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
|
Material | ||
Housing | PA 66-FR | |
Mounting | DIN mounting rail |