来源:未知 日期:2017/03/07 浏览量:次
| 产品阐述: | ||
|---|---|---|
| AS-Interface enabling switch, 3-layered | ||
| General specifications: | ||
|---|---|---|
| Slave type | Safety-Slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | ≥ V2.0 | |
| Switching principle | slow-acting contact element, 3-stage | |
| UL File Number | E179102 | |
| Functional safety related parameters: | ||
| Performance level (PL) | PL d | |
| B10d | 1 E+5 | |
| Electrical specifications: | ||
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
| Rated operating current | ≤ 45 mA | |
| Rated insulation voltage | 50 V | |
| Input: | ||
| Number/Type |
2 safety-related inputs: NO E1 NO E2 |
|
| Supply | from AS-Interface | |
| Compliance with standards and directives: | ||
| Directive conformity | ||
| EMC Directive 2004/108/EC | EN 50295, IEC 62026-2 | |
| Standard conformity | ||
| Functional safety | DIN EN 954-1, EN ISO 13849-1 (up to PLd) | |
| Programming instructions: | ||
| Profile | S-0.B | |
| IO code | 0 | |
| ID code | B | |
| ID1 code | F | |
| ID2 code | E | |
| Data bits (function via AS-Interface) | Input | |
| D0 | dyn. safety code 1 | |
| D1 | dyn. safety code 1 | |
| D2 | dyn. safety code 2 | |
| D3 | dyn. safety code 2 | |
| Ambient conditions: | ||
| Ambient temperature | -5 ... 50 °C (23 ... 122 °F) | |
| Mechanical specifications: | ||
| Degree of protection | IP67 | |
| Connection | M12 x 1 connector | |
| Material | ||
| Housing | Polyamide (PA) | |
| Protective cover | Neoprene | |
| Mass | approx. 140 g (without conduction) | |
| Life span | 105 cycles | |