来源:未知 日期:2018/01/22 浏览量:次
| 产品阐述: | ||
|---|---|---|
|
G11 analog module 4 analog outputs |
||
| 一般特性: | ||
|---|---|---|
| Slave type | Standard slave | |
| AS-Interface specification | V3.0 | |
| Required master specification | ≥ V2.1 | |
| UL File Number | E223772 | |
| 功能安全性参数: | ||
| MTTFd | 220 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| 指示灯/操作键: | ||
| LED AS-i/FAULT |
Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: peripheral fault |
|
| LED ANALOG |
Status of output signal; yellow LED Yellow: Output value within range Yellow flashing: lead breakage (on current output) or output value out of range |
|
| LED AUX |
ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
|
| LED INT/EXT |
status display output supply; LED green green: output supply from AS-Interface off: output supply from auxiliary voltage |
|
| 电气特性: | ||
| Auxiliary voltage (output) | 24 V DC ± 15 % PELV | |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface | |
| Rated operating current | ≤ 75 mA (without outputs) / max. 200 mA | |
| Protection class | III | |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) | |
| 输出: | ||
| Number/Type |
4 analog outputs Current: 0 ... 20 mA Voltage: 0 ... 10 V |
|
| Supply | from AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) | |
| Load |
voltage output: min. 1 kΩ current output: max. 600 Ω |
|
| Current loading capacity |
≤ 120 mA (signal current + actuator supply) from AS-Interface; overload and short-circuit protected ≤ 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected |
|
| Resolution |
Voltage output: 3 mV Current output: 6 µA |
|
| Accuracy | 0.15 % of full-scale value | |
| Temperature influence | 1 µA/K or 0,3 mV/K | |
| Short-circuit current | voltage output: max. 22 mA | |
| 与标准和规范体系的一致性: | ||
| Directive conformity | ||
| EMC Directive 2004/108/EC | EN 50295:1999 | |
| Standard conformity | ||
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, IEC 62026-2:2008 | |
| Emitted interference | EN 61000-6-4:2007 | |
| Degree of protection | EN 60529:2000 | |
| Fieldbus standard | EN 50295:1999, IEC 62026-2:2008 | |
| 编程指令: | ||
| Profile | S-7.3.6 | |
| IO code | 7 | |
| ID code | 3 | |
| ID1 code | F | |
| ID2 code | 6 | |
| Data bits (function via AS-Interface) | The transfer of the data value is based on AS-Interface Profile 7.3. | |
| Parameter bits (programmable via AS-i) | 功能 | |
| P0 |
Watchdog: P0=1 (default), watchdog active P0=0, watchdog inactive |
|
| P1 |
Output mode: P1=1 (default), 4x current output P2=0, 4x voltage output |
|
| P2 |
Indication of peripheral fault: P2=1 (default), peripheral fault is reported P2=0, peripheral fault is not reported |
|
| P3 |
Automatic mode: P3=1 (default), manual setting of output mode P3=0, automatic load detection (mixed mode possible) |
|
| 周围环境: | ||
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 85 % , noncondensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 2000 m above MSL | |
| Pollution degree | 3 | |
| 机械特性: | ||
| Degree of protection | IP68 / IP69K | |
| Connection |
AS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Outputs: M12 round connector |
|
| Material | ||
| Housing | PBT PC | |
| Mounting screw | Stainless steel 1.4305 / AISI 303 | |
| Mass | 200 g | |
| Tightening torque, housing screws | 1.8 Nm | |
| Tightening torque, cable gland | 0.4 Nm | |
| Mounting | Mounting plate | |