来源:未知 日期:2018/08/09 浏览量:次
产品阐述: | ||
---|---|---|
Distance sensor |
一般特性: | ||
---|---|---|
Measurement range | 100 ... 300 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | LED | |
Light type | modulated visible red light | |
LED risk group labelling | exempt group | |
Angle deviation | max. +/- 1.5 ° | |
Diameter of the light spot | approx. 8 mm at a distance of 300 mm | |
Angle of divergence | 1.8 ° | |
Ambient light limit | EN 60947-5-2 : 45000 Lux | |
Resolution | 0.1 mm | |
功能安全性参数: | ||
MTTFd | 600 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
指示灯/操作键: | ||
Operation indicator |
LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Function indicator |
LED yellow: constantly on - switch output active constantly off - switch output inactive |
|
Control elements | Teach-In key | |
Control elements | 5-step rotary switch for operating modes selection | |
电气特性: | ||
Operating voltage | 10 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 25 mA at 24 V supply voltage | |
Protection class | III | |
接口: | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile |
Identification and diagnosis Smart Sensor type 0/type 3.3 |
|
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 3 ms | |
Process data witdh | Process data input 4 byte Process data output 2 bits | |
SIO mode support | yes | |
Device ID | 0x111914 (1120532) | |
Compatible master port type | A | |
输出: | ||
Switching type |
The default setting is: C/Q - BK: NPN normally open, PNP normally closed, IO-Link Q2 - WH: NPN normally open, PNP normally closed |
|
Signal output | 2 push-pull (4 in 1)outputs, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Response time | 2 ms , see table 1 | |
符合: | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
测量精度: | ||
Temperature drift | 0.05 %/K | |
Warm up time | 5 min | |
Repeat accuracy | < 0.5 % , see table 1 | |
Linearity error | 0.5 % | |
许可和认证: | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
周围环境: | ||
Ambient temperature | 10 ... 60 °C (50 ... 140 °F) | |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
机械特性: | ||
Housing width | 15 mm | |
Housing height | 61.7 mm | |
Housing depth | 41.7 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | 2 m fixed cable | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 73 g | |
Cable length | 2 m |