| 产品阐述: | ||
|---|---|---|
| Single head system | ||
| 一般特性: | ||
|---|---|---|
| Sensing range | 200 ... 4000 mm | |
| Adjustment range | 240 ... 4000 mm | |
| Dead band | 0 ... 200 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 85 kHz | |
| Response delay | approx. 325 ms | |
| 指示灯/操作键: | ||
| LED green | solid green: Power on | |
| LED yellow |
solid: switching state switch output flashing: program function |
|
| LED red |
normal operation: "fault" program function: no object detected |
|
| 电气特性: | ||
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS | |
| No-load supply current | ≤ 60 mA | |
| 输入/输出: | ||
| Synchronization |
bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
|
| Synchronization frequency | ||
| Common mode operation | max. 13 Hz | |
| Multiplex operation | ≤ 13/n Hz, n = number of sensors | |
| 输出: | ||
| Output type | 1 switching output E5, PNP NO/NC, programmable | |
| Rated operating current | 200 mA , short-circuit/overload protected | |
| Default setting | Switch point A1: 240 mm , Switch point A2: 4000 mm , wide sound lobe | |
| Voltage drop | ≤ 2.5 V | |
| Repeat accuracy | ≤ 0.5 % of switching point | |
| Switching frequency | ≤ 1.2 Hz | |
| Range hysteresis | 1 % of the set operating distance | |
| Temperature influence | ± 1 % of full-scale value | |
| 许可和认证: | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V | |
| 周围环境: | ||
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| 机械特性: | ||
| Connection type | Connector M12 x 1 , 5-pin | |
| Degree of protection | IP54 | |
| Material | ||
| Housing | ABS | |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Mass | 150 g | |