振动限位开关 LVL-M2H

来源:未知    日期:2017/08/29    浏览量:


如今,液位测量技术是化学、化工、环境和相关行业中过程控制管理的基本技术。倍加福可帮助用户解决特殊测量和控制问题,并且能够精确的检测任何介质的液位。

限位检测开关在介质达到设定高度、超过设定值或者低于设定值的时候进行切换信号。 设定值(VDI/VDE Directive 3519)基于安装高度。

音叉液/料位测量仪的工作模式:两片音叉在使用中由压电器件振动。在空气中音叉有一个固定振动频率。当遇到液体时,音叉频率和振幅发生改变。电路检测到这些变化并产生开关信号。

在用有振动式限位开关测量限位时,将棒或音叉置于振动中。如果振动探头与介质发生接触,则振动会发生改变,振动式限位开关发出一个开关指令。将振动式限位开关作为溢流保护装置或空载报告器用于液体中以及颗粒状的或粉末状的固料中。

该装置是一个坚固的筒仓水平限位开关—粒或粗粒,非流态化固体。各种各样的设计意味着这个装置的范围很广。可在灰尘中使用易燃危险区。

典型的应用:谷物,咖啡豆,糖,动物饲料,大米,洗涤剂,染料粉、粉笔、石膏、水泥、砂、塑料颗粒。

产品特点:● Limit switch in hygienic version for liquids
               ● Large selection of process connections: universal use
               ● Wide variety of electronic modules (e. g., relay, thyristor signal output): the right connection for every process control system
               ● No calibration: quick and low-cost start up
               ● No mechanically moving parts: maintenance-free, no wear, long operating life
               ● Monitoring of the vibrating fork for damage: guaranteed function
               ● PROFIBUS PA protocol: commissioning and maintenance quick and easy
               ● Process connections acc. to EHEDG
               ● Up to SIL 2 acc. to IEC 61508


一般特性:
Function principle limit detection
Maximum or minimum detection in tanks or pipelines containing all types of liquids including use in explosion hazardous areas. Particularly suited to very aggressive liquids thanks to high degree of corrosion protection.
Measuring method The forks of the sensors vibrate at their intrinsic frequency. This frequency is reduced when covered with liquid.
The change in frequency then activates the limit switch.
Construction type device with extension tube
Supply:
Rated voltage electronic insert FEL50A (PA): 9 ... 32 V DC
electronic insert FEL51 (AC): 253 V AC, 50/60 Hz
electronic insert FEL52 (E5): 10 ... 55 V DC
electronic insert FEL54 (WA): 19 ... 253 V AC, 50/60 Hz or 19 ... 55 V DC
electronic insert FEL55 (SI): 11 ... 36 V DC, PLC
electronic insert FEL56 (N1), FEL58 (N2): isolating amplifier acc. to EN 60947-5-6 (NAMUR)
Current consumption electronic insert FEL52 (E5): max. 15 mA
电气特性:
Surge protection electronic insert FEL51 (AC), electronic insert FEL52 (E5), electronic insert FEL54 (WA), electronic insert FEL55 (SI): overvoltage category III
输入:
Switching point see section switch point
Measured variable limit level (limit value)
Measurement range depends on mounting point and pipe extension up to 3000 mm , larger sizes on request
输出:
Switching delay when fork is covered: approx. 0.5 s, when fork is exposed: approx. 1.0 s (other switching times on request)
additionally configurable for PROFIBUS PA (electronic insert FEL50A (PA)): 0.5 ... 60 s
Switch behaviour switch-over for minimum/maximum residual current safety on electronic insert
MAX = maximum safety:
The output switches to the power fail response when the fork is covered.
for use with overspill protection for example
MIN = minimum safety:
The output switches to the power fail response when the fork is exposed.
for use with dry running protection for example
When switching on the power supply the output assumes the alarm signal. After max. 2 s it assumes the correct switching mode.
符合:
Electromagnetic compatibility NE 21
Degree of protection IEC 60529
Vibration resistance EN 60068-2-6
Climate class DIN EN 60068-2-38/IEC 68-2-38
测量精度:
Reference operating conditions ambient temperature: 23 °C (73.4 °F), medium temperature: 23 °C (73.4 °F),
product density: 1 g/cm3 (water), viscosity: 1 mm2/s, medium pressure pe: 0 bar,
sensor mounting: vertical from above, density switch: to > 0.7 g/cm3
Maximum measured error max. ± 1 mm, specified by mounting position
Non-repeatability 0.1 mm
Hysteresis approx. 2 mm
Influence of medium density max. +4.8 ... -3.5 mm (0.5 ... 1.5 g/cm3)
Influence of medium temperature max. +1.4 ... -2.8 mm (-40 ... 150 °C (-40 ... 302 °F))
Influence of medium pressure max. 0 ... -2.5 mm (-1 ... 64 bar)
操作条件:
Installation conditions  
  Installation position with short pipe (up to 500 mm (19.7 inch)) any position, with long pipe vertical
Process conditions  
  Medium temperature -50 ... 150 °C (-58 ... 302 °F) , exceptions see process connections
  Medium pressure pe = -1 ... 64 bar (-14.5 ... 928.3 psi) over the entire temperature range , exceptions see process connections
  Test pressure max. 100 bar (1.5 times the medium pressure pe), no function during test pressure, burst pressure of diaphragm 200 bar
  Thermal shock resistance max. 120 °C/s (max. 120 K/s)
  State of aggregation liquid
  Density min. 0.5 g/cm3 (compact housing 0.7 g/cm3), other density settings on request
  Viscosity max. 10000 mm2/s (max. 10000 cSt)
  Solid contents < ∅5 mm
周围环境:
Ambient temperature -50 ... 70 °C (-58 ... 158 °F) , function with reduced data values
see section ambient temperature
Storage temperature -50 ... 80 °C (-58 ... 176 °F)
Vibration resistance 10 ... 50 Hz, 0.15 mm, 100 cycles
机械特性:
Degree of protection polyester, steel, and aluminum housing: IP66/IP67
compact housing:
- IP65 with valve connector PG11 or 1/2NPT
- IP66/IP68 with M12 x 1 connector without LEDs (1.4435/316L)
- IP69K with M12 x 1 connector with LEDs (1.4435/316L)
Connection electronic inserts: cross section max. 2.5 mm2, lace in end splice in acc. with DIN 46228
ground lead in housing: cross section max. 2.5 mm2
external equipotential bonding: cross section 4 mm2
Material wetted parts:
- process connection and extension tube: 1.4435/316L
- vibration fork: 1.4435/316L
- flat seal for process connection G2* or G3*: elastomer fibre, asbestos-free
housings:
- polyester housing: PBT-FR with PBT-FR cover or with PA12 cover with sight glass, cover seal: EPDM
- stainless steel housing: 1.4435/316L, cover seal: silicone
- aluminum housing: EN-AC-AlSi10Mg, plastic-coated, cover seal: EPDM
- compact housing with valve connector or M12 connector: 1.4435/316L
cable gland: polyamide or brass, nickel-plated
temperature spacer: 1.4435/316L
flameproof bushing: 1.4435/316L
Surface quality Ra < 1.5 µm/120 grit: length, spacer, bushings *C
Ra < 0.3 µm/320 grit: length, spacer, bushings *D
Mass 700 g , basic weight: compact sensor, electronic insert, stainless steel housing, process connection G2*, additional weight is dependent on extension tube, housing and process connection
process connections:
- A31 1000 g, A41 1200 g, A51 1500 g, A6* 2400 g, A72 4800 g, A81 4900 g, A82 6800 g, A91 7000 g,
A92 11.5 kg
- D75 3200 g, D95 5900 g, DA3 5600 g, D7A 300 g, D7D 300 g
- F45 1400 g, F51 1200 g, F55 2000 g, F61 1400 g, F65 2400 g, F71 1600 g, F75 3200 g,
F81 2400 g, F85 4300 g, F93 4800 g, F95 5900 g, FA3 5600 g, FA5 7500 g
- G3E 200 g
- J13 no information, J16 no information, J17 1700 g, J19 no information, J1A no information, J1C 1700 g
- R*R no information
- S13 300 g, S61 200 g, SV1 no information
- T51 no information, T61 100 g
extension tube, tempeprature spacers, flameproof bushings:
- B* 900 g/m, C* 2300 g/100 inch
- D* 100 g
- J* 900 g/m and 600 g, K* 2300 g/100 inch and 600 g
- L* 700 g
- R* 900 g/m and 700 g, S* 2300 g/100 inch and 700 g
- T* 800 g
Dimensions housing: diameter max. 85 mm, height max. 173 mm
temperature separator, flameproof bushing: additional length L 140 mm
process connection: length L 55.5 ... 80 mm
extension: any length L from 148 ... 3000 mm, larger sizes on request
extension: length type II, for vertical installation from above same switching point as
Vibracon LVL1, LVL2
vibration fork: width 17.5 mm, fork width 10 mm, length 25 mm
Process connection - cylindrical thread G3/4A, G1A to DIN ISO 228/1 with flat seal to DIN 7603
- conical thread R3/4, R1 to DIN 2999, part 1
- flush-mounted with welding sleeve to factory standard (G3/4A, G1A)
- flush-mounted with welding neck to factory standard (1 inch), sensor can be positioned
- Triclamp 1-1/2 inch, 2 inch to ISO 2852
- threaded pipe joint DN32, DN40, DN50 to DIN 1185
- aseptic connection DN50 to DIN 11864-1 form A for pipe DIN 11850
- SMS connection 2 inch (DN51)
- DRD flange, 65 mm
- Varivent® DN50 (50/40) to factory standard Tuchenhagen
- flanges to EN 1092-1 from DN25, to ANSI B 16.5 from 1 inch, to JIS B 2238 (RF) from DN25
For further information see type code.
与危险区域有关的应用数据:
EU-Type Examination Certificate see instruction manuals (SI)
国际认证:
FM approval see control drawings (ZD)
CSA approval see control drawings (ZD)
IECEx approval see instruction manuals (SI)
许可和认证:
SIL classification up to SIL2 acc. to IEC 61508
Overspill protection see approval (ZE)
附件:
Designation see technical information (TI)


      如果您对以上产品有兴趣或有疑问,请联系我们的在线客服或拨打021-39520660,上海锝秉工控专业的采购顾问将为您提供最优的采购咨询服务。

      物流运输更安全! 在上海锝秉工控货品运输的费用从未被加进您所购买产品的售价中。只要您需要,我们就会免费为您提供服务。在运输方式上,上海锝秉工控一般采用快递方式发货,因为快递一般注重产品安全,打包时里面会装有海棉等填充物,这样可以避免运输途中的损坏,同时快递运输时间短,从而也减少客户的等待。

      我们一起省钱! 当您需要订购上海锝秉工控产品时,如我们库存有现货,您需支付全部货款,我们给您发货,如果是期货的,您需先支付30%定金,货到我们公司后您再支付100%的货款,您的及时付款是对我们工作的支持,同时也为我们节省了财务成本,这也是我们能一贯保持优质低价的原因之一。欢迎您的参与,让我们一起省钱吧!

      用心服务客户至上! 在上海锝秉工控购买的产品,可以享有上海锝秉工控强大的技术团队为您提供一对一的技术支持服务!在产品使用过程中,您遇到任何产品安装或是调试的问题,都可以随时联系我们,我们必定尽心尽力为您服务。用心服务,客户至上是我们服务的宗旨!